V. Moiseenko on how to make a cheap portrait lens — a plano-convex “monocle” ordered from an optician for 5–6 roubles, whose very chromatic aberration gives the soft drawing a portrait wants. How to specify it in diopters, build its mount from a coffee-tin (with or without changeable diaphragms), compute the diaphragms and the ray-path for the mount, and — since the monocle focuses sharp in the chemical, not the optical, focus — two home-made devices for applying the “focal difference” correction (and varying the softness at will).
All amateur cameras on sale are usually supplied with lenses little suitable for portrait shooting. Firstly, they have a short focal distance, thanks to which they give too small an image; and secondly, they draw too sharply, which is not at all useful at portrait shooting. Ready portrait lenses at present are not on our market. For an amateur wishing to take up portrait shooting, and having besides limited means, the only way out is the making of a monocle lens.
A monocle is a lens consisting of one uncemented glass, plano-convex or concavo-convex. If there is no possibility to make two monocles at once, it is better first to stop on a monocle consisting of plano-convex glass, turned with the flat side to the plate. The spherical aberration of such glass is small; the astigmatism, in consequence of using at portrait shooting a small angle of view, also does not make itself felt; the distortion of the image at the edges of the plate for portraits has no significance. As for chromatic aberration, then in the given case it is only useful, since it is precisely it that conditions the softness of drawing desirable for a portrait.
Choosing the glass
The most suitable size of image for an amateur portrait I consider 9×12 cm. Plates of larger size cost rather dear; 6×9 cm is already too small. The said, of course, does not relate to the size of the camera, since a camera 9×12 cm even with double bellows extension will unconditionally be small. One needs either a camera 18×24 cm with double extension, or 13×18 cm with triple, or, what is much more accessible, a home-made attachment to the existing camera. I, for example, to an old camera 13×18 cm with single extension, built in front a plywood box, on the front wall of which I fixed the monocle described below.
To determine in advance the minimal sizes of the camera needed for the given portrait lens, one must calculate the distance between the lens and the ground glass corresponding to a 2-metre distance to the object of shooting. This distance is calculated by formula (1):
f = (p − F) / (F · d) (1)
In this formula (f) is the sought distance, (F) the main focal distance of the lens, and (d) the distance to the object being shot, in the given case equal to 2 metres. The minimal focal distance of a portrait lens for a 9×12 plate is 25 cm, but, in my opinion, it is better to take 30–40 cm. The diameter (width) of the glass is desirable such that the ratio of the focal distance to the diameter should be not more than 5–6.
Such glasses at present are not on sale, and therefore the glass will have to be ordered from an optician. The cost of such a glass, made to order in Moscow, is 5–6 roubles. I was recently made a glass with a focal distance of 40 cm and a diameter of 7 cm for 6 roubles. I draw the readers’ attention to the circumstance that when ordering it is better to indicate not the focal distance but the power of the glass expressed in diopters — this is more understandable to opticians. To go from the focal distance to the power of the glass expressed in diopters, one must divide unity by the focal distance expressed in metres. For example: a focal distance of 40 cm (i.e. 0.40 metre) corresponds to 2.5 diopters, since 1:0.40 = 2.5; 36.4 cm — 2.75 diopters; 28.6 cm — 3.5 diopters, and so on.
The mount
The mount for the lens is simplest to make oneself. I made myself a mount from a tin coffee-box. Drawing 1 gives an idea of the construction of my mount: (a) — the tin box, in the bottom of which I made a round hole of 66 mm; (b) — the glass; (c) — black paper with a round opening of 64 mm; (d) — a plywood ring cut with a fretsaw; (e) — black paper; (f) — a plywood ring; (g) — a cardboard disc centring the glass; (h) — a lid made of cardboard and pasted outside with black paper, and inside with black velvet. The plywood ring (f) I made first by outer diameter somewhat larger than the inner diameter of the tin, and then with a file and sandpaper fitted it to the tin so that it entered it with friction and would thus hold the glass in its place. This ring serves for the screwing of the lens to the camera. In essence, for an amateur monocle a better mount is not even needed.
If someone wishes to have a mount allowing the changing of the diaphragms, then this is easily arranged from a taller coffee-box. Drawing 2 gives the construction of such a mount: (i) — a cardboard tube; (k) — a plywood ring on which the glass rests; (l) — a plywood or cardboard ring; (m) — a cardboard ring with a cut-out of the form given in a separate sketch; and finally (n) — again a plywood ring. The rings (h, m and n) should be glued together, but here one must watch that glue does not get into the slit between rings (m) and (n): this slit will serve for the insertion of the diaphragm. The diaphragms (o) should be made of somewhat thinner cardboard than ring (h). All parts of the mount, not excluding the diaphragms themselves, should be either pasted with black matte paper or painted with black matte paint, for example India ink.
As is seen from drawing 2, the diaphragm is placed behind the glass. Such a position in the given case is advantageous in consequence of some reduction of astigmatism, though one must say that the difference between the front and back arrangements in the given case is not great. The distance of the diaphragm from the glass is better made about half or the whole diameter of the glass. Portraits are always shot with the full aperture of the lens, and therefore the described device of a mount with changeable diaphragms is necessary only if one intends to use the lens also for view shooting.
Why the image is soft; the diaphragms and the ray-path
The long-focus monocle described above, made of plano-convex glass, can be used for view shooting only as a telephoto lens, since for ordinary view shooting it is not fit in consequence of the small angle of view and the uneven distribution of sharpness over the image. The middle of the image — i.e. approximately the place where mainly the face of the portrait is located — has much greater sharpness, gradually decreasing toward the edges of the plate.
The necessary diameters of diaphragms, in the case of their rear arrangement, for plano-convex glass are calculated by formula (2):
d = (F − x) / n (2)
In this formula (F) is the main focal distance, (x) the distance from the diaphragm to the glass added with half the thickness of the glass, and (n) the light-power. In case of the front arrangement of the diaphragm, the necessary diameters are calculated by formula (3):
d = F / n (3)
In these formulas (d) is the sought diameter (width) of the diaphragm. To determine the sizes of the mount itself, its diameter and length, one must draw for the given glass the course of the rays at focusing on a distant object, since precisely in this case the extreme rays give the widest bundle, which determines the size of the mount. On drawing 3 it is shown how to draw the course of the rays: (a, b) — the diagonal of the plate; (F) — the main focal distance (for chemical rays); (d) — the diaphragm; (o) — the optical centre of the glass, which for plano-convex glass is at the intersection of the main optical axis with the spherical surface. The mount should be made so that the extreme bundles freely pass through it, but at the same time so that excess light does not get into the camera.
As already said, all monocles give a soft image — this is conditioned by chromatic aberration. The phenomenon of chromatic aberration consists in that the focuses of various rays of the spectrum are obtained not in one plane. Namely, the violet part of the spectrum is collected in a focus located closer to the lens (the chemical focus), and the yellow — farther (the optical focus). The images given by a monocle are obtained therefore as if consisting of an infinitely large number of images superimposed on each other: one sharp and the rest decreasing in sharpness. The natural softness of images given by a monocle almost frees the photographer from retouch. But this is little; the monocle has yet another property very important for artistic photography: the degree of softness of the image it gives can be varied at the photographer’s wish to a rather wide degree. This has significance for the strengthening of the artistic effect of a shot by the selection for the given subject of the best degree of softness.
The focal difference, and two devices for it
At focusing on focus by the ground glass we usually set the plate in the focus of the yellow rays, as the most bright for the eye, or, as they say, in the optical focus. To get the sharpest shot, one must move the rear frame of the camera forward (or the lens board back) by a magnitude equal to the distance between the optical and chemical focus. This magnitude is called the focal difference. Its magnitude depends on the main focal distance of the lens and on the extension of the camera bellows. Formula (4) gives the possibility to calculate the focal differences:
Δf = 0.02 · p / F (4)
In the formula, (p) is the distance of the ground glass from the lens at the sharp setting to focus (the given bellows extension), (Δf) the focal difference, and (F) the focal distance of the lens. By this formula, for each given monocle one can compose a table or graph giving the dependence of the focal difference on the extension of the bellows. At shooting, after focusing, one can measure the distance between the lens and the ground glass (the bellows extension), find by the table the focal difference, and move the rear frame of the camera forward to the lens by this difference.
To simplify this manipulation, a number of devices were proposed. I shall describe only two most simple ones. The first device consists in the following. On the lower board of the camera two longitudinal strips of paper are pasted, and on them scales with divisions are made: on one strip with black ink, on the other with red. On the black scale are marked the distances from the lens to the ground glass, i.e. the bellows extension at ordinary (optical) focusing; on the red one are marked the corresponding distances at focusing on the chemical focus. On both scales are written the same numbers. The work: after focusing by the ground glass, remember the division of the black scale through which passes the edge of the rear frame of the camera, then move the frame forward until its edge crosses the division of the red scale against which is written the same number. By this the full correction on the focal difference is achieved; for a partial correction, move the frame by a corresponding part of the distance between the indicated divisions.
The device I propose consists (drawing 4) of a plate (a), cut into or pasted onto the lower board of the camera, and a movable indicator (b) freely moving along a rail (c). On plate (a) two lines are drawn: one (d) — an inclined straight line — and the other (e) — a curve. The incline of (d) is arbitrary. The curve (e) is built from the focal differences calculated by formula (4) for a series of points along (d) — the ends of the plotted correction-segments being joined by the curve, better drawn in red so that it sharply differs from the straight line (d). The indicator (b) is made sufficiently thin, and the rail (c) fixed so that the sharp end of the indicator, at its movement, draws a line practically coinciding with the edge of the rear frame of the camera. The work: after focusing on focus by the ground glass, move the indicator (b) to the inclined straight line (d), and then the rear frame of the camera forward until the indicator (b) touches the curve (e). By this simple manipulation the full correction on the focal difference is achieved; a partial correction is got by moving the rear frame by a corresponding part of the distance between the straight line (d) and the curve (e).
The second of the described devices has the advantage over the first of the greater mechanicalness of introducing the correction — indeed, here one need not remember any numbers; the first device is somewhat simpler to make by home means.
I work with a monocle of the described type: its diameter is 7 cm, its focal distance 40 cm, and its light-power 6.3.
— V. Moiseenko